TH

Calibration

CALIBRATION · ISO/IEC 17025 No. 0383
Reference mass standards used in our calibration laboratory

Our calibration laboratory is accredited to ISO/IEC 17025 by NSC-TISI (accreditation No. 0383). Every certificate is traceable to the national standard and recognised worldwide through the ilac-MRA.

  • ilac-MRAilac-MRAInternational mutual recognition arrangement
  • NAC ThailandNAC ThailandNSC-TISI-TIS 17025 · Calibration 0383
  • ISO/IEC17025Testing & calibration laboratoriesISO/IEC 17025The standard our laboratory is accredited to

Calibration you can trace

TRACEABLE CALIBRATION
  1. National standard

    NIMT Thailand

  2. Reference standard

    held and re-certified in our lab

  3. Working standard

    what our engineers carry to your site

  4. Your instrument

    with certificate

Every certificate we issue traces back to the national standard.

The laboratory

ห้องปฏิบัติการสอบเทียบ

The laboratory of CG Engineering calibrates measuring and testing instruments for rubber and plastics, on site at your plant, to ISO/IEC 17025. It is staffed by trained personnel and works to standardised methods with standard equipment traceable to SI units, so results hold up metrologically.

The laboratory was first accredited to ISO/IEC 17025:1999 E (TIS 17025-2000) in 2004, under calibration certification number 0108. The certification was then renewed and updated to ISO/IEC 17025:2005 E on 9 March 2006.

The scope of certification of calibration methods gradually expanded. In 2016 certification number 0108 was withdrawn on relocation of the laboratory, and the lab was recertified to ISO/IEC 17025:2005 on 29 January 2016 by the Thai Industrial Standards Institute (TISI), under calibration certification number 0267.

The laboratory renewed the certificate to ISO/IEC 17025:2017 E (TIS 17025-2018) on 10 January 2019, and improves the quality of its calibration work continuously to serve a growing customer base — from around 15 customers at the beginning to 289 today.

Where we work

Domestic
Rubber industry · Plastic industry · Government organisations
International
Vietnam · Singapore · Indonesia · Malaysia · Cambodia · Myanmar · China · Ivory Coast · France · England

Calibration scope

ขอบข่ายการสอบเทียบ

Our laboratory’s calibration scope, by instrument type. Every figure is transcribed from the published scope document — nothing rounded, nothing inferred.

Rheometer (MDR / RPA / ODR)

Rheometer (MDR & RPA)

Temperature AccuracyOn the accredited schedule
Parameter / Range / ItemCalibration measurement capability
100 to 210 °C± 0.50 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-07 by direct comparison to standard Thermometer.

Torque verification — Degree of Verify
Parameter / Range / ItemCalibration measurement capability
0.5 Degree.± 1.60%
1.0 Degree± 1.60%
3.0 Degree± 1.60%

Standard / Technique / Method / EquipmentIn-house method WI 7.2-15 Verification by Standard Torque

Speed of Die
Parameter / Range / ItemCalibration measurement capability
100 cpm± 0.1 cpm

Standard / Technique / Method / EquipmentIn-house method WI 7.2-17 by measurement with Standard Stopwatch.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Rheometer (Only ODR type)

Temperature AccuracyOn the accredited schedule
Parameter / Range / ItemCalibration measurement capability
100 to 200 °C± 0.40 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-06 by direct comparison to standard Thermometer.

Torque verification — Degree of Verify
Parameter / Range / ItemCalibration measurement capability
0.5 Degree.± 1.60%
1.0 Degree± 1.60%
3.0 Degree± 1.60%

Standard / Technique / Method / EquipmentIn-house method WI 7.2-15 Verification by Standard Torque

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Mooney Viscometer

Temperature AccuracyOn the accredited schedule
Parameter / Range / ItemCalibration measurement capability
85 to 145 °C± 0.35 °C
>145 to 160 °C± 0.37 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-06 by direct comparison to standard Thermometer.

Torque (100 MU) — Torque Verify by Butyl Rubber, IRM-241
Parameter / Range / ItemCalibration measurement capability
ML1+4@100 °C± 0.5 MU
ML1+8@100 °C± 0.5 MU
ML1+4@125 °C± 0.5 MU
ML1+8@125 °C± 0.5 MU

Standard / Technique / Method / EquipmentIn-house method WI 7.2-16 Verification by Standard material (IRM-241)

Mass
Parameter / Range / ItemCalibration measurement capability
4 to 15 kg± 0.3 g.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-01 by comparison with standard weight and Electronic balance.

Speed of Rotor
Parameter / Range / ItemCalibration measurement capability
2 rpm± 0.03 rpm

Standard / Technique / Method / EquipmentIn-house method WI 7.2-17 by measurement with Standard Stopwatch.

Timer — Pre-heat Time / Testing Time
Parameter / Range / ItemCalibration measurement capability
1 min± 0.1 Seconds
4 min± 0.1 Seconds

Standard / Technique / Method / EquipmentIn-house method WI 7.2-17 by measurement with Standard Stopwatch.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Tensile Tester / Universal Testing Machine

Force, Tension modeOn the accredited schedule
Parameter / Range / ItemCalibration measurement capability
4 to <100 Newton± 0.06 Newton
100 to <1,000 Newton± 0.47 Newton

Standard / Technique / Method / EquipmentISO 7500-1:2004 (E) /Standard weight. & Standard Loadcell.

Speed verification
Parameter / Range / ItemCalibration measurement capability
50 mm./min± 0.5 mm./min
100 mm./min± 0.5 mm./min
200 mm./min± 0.5 mm./min
300 mm./min± 0.5 mm./min
400 mm./min± 0.5 mm./min
500 mm./min± 0.5 mm./min

Standard / Technique / Method / EquipmentIn-house method WI 7.2-17 Verification by Standard stopwatch and Vernier caliper.

Distance (Extensometer)
Parameter / Range / ItemCalibration measurement capability
100 % (Gauge 2 cm.)± 1.5 %
200 %(Gauge 2 cm.)± 1.5 %
300 %(Gauge 2 cm.)± 1.5 %
400 %(Gauge 2 cm.)± 1.5 %
500 %(Gauge 2 cm.)± 1.5 %

Standard / Technique / Method / EquipmentIn-house method WI 7.2-17 by direct comparison to standard gauge block.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Melt Indexer

Temperature Accuracy and DistributionOn the accredited schedule
Parameter / Range / ItemCalibration measurement capability
190 to 300 °C± 0.44 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-21 by direct comparison to standard Thermometer.

Temperature Recovery
Parameter / Range / ItemCalibration measurement capability
190 to 350 °C- °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-11 Verification by Standard stopwatch.

Mass
Parameter / Range / ItemCalibration measurement capability
100.0 to 500.0 g.± 0.2 g.
500.0 to 1000.0 g.± 0.3 g.
1000.0 to 10000.0 g.± 0.3 g.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-01 by comparison with standard weight.

Dimension — Accessory, Diameter of Piston
Parameter / Range / ItemCalibration measurement capability
8.890 mm.± 0.002 mm.
9.474 mm.± 0.002 mm.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-11 by comparison with standard Micrometer.

Accessory, Diameter of Orifice
Parameter / Range / ItemCalibration measurement capability
8.000mm.± 0.002 mm.
9.500mm.± 0.002 mm.
2.095mm.± 0.002 mm.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-11 by comparison with standard Micrometer and comparison to standard Diameter gauge.

Accessory, Diameter of Go gauge & No go gauge
Parameter / Range / ItemCalibration measurement capability
2.090mm.± 0.001 mm.
2.100mm.± 0.001 mm.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-11 by comparison with standard Micrometer.

Diameter of Cylinder
Parameter / Range / ItemCalibration measurement capability
9.550 mm.± 0.003 mm.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-11 by comparison with standard Diameter gauge.

Distance of Flow rate
Parameter / Range / ItemCalibration measurement capability
1.00-20.00 mm.± 0.008 mm.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-12 by comparison with standard Micrometer head.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

HDT / Vicat Tester

Temperature AccuracyOn the accredited schedule
Parameter / Range / ItemCalibration measurement capability
50 to 100 °C± 0.27 °C
>100 to 200 °C± 0.35 °C
>200 to 350 °C± 0.45 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-05 by direct comparison to standard Thermometer.

Temperature Heating
Parameter / Range / ItemCalibration measurement capability
50 to 300 °C0.45 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-14 Verification by standard Thermometer and Standard stopwatch.

Mass
Parameter / Range / ItemCalibration measurement capability
100.0 to 500.0 g.± 0.2 g.
500.0 to 1000.0 g.± 0.3 g.
1000.0 to 10000.0 g.± 0.3 g.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-01 by comparison with standard weight.

Dimension — Distance of differential transformer
Parameter / Range / ItemCalibration measurement capability
– 0.5 to 2.5 mm.± 0.003 mm.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-13 by comparison with Micrometer Head.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Impact Tester

Torque capacity — Torque verification
Parameter / Range / ItemCalibration measurement capability
1.0- <10.0 N.m± 0.1 %
10.0- <20.0 N.m± 0.1 %
20.0- <30.0 N.m± 0.1 %

Standard / Technique / Method / EquipmentIn-house method WI 7.2-10 by direct measurement to standard Electronic balance.

Period Verification
Parameter / Range / ItemCalibration measurement capability
- All hammer± 0.7 %

Standard / Technique / Method / EquipmentIn-house method WI 7.2-10 by measurement to standard Stopwatch.

Arm moment verification
Parameter / Range / ItemCalibration measurement capability
150 -600 mm.± 1.30 %

Standard / Technique / Method / EquipmentIn-house method WI 7.2-10 by measurement to standard Stopwatch.

Dimension — Distance’s support sample
Parameter / Range / ItemCalibration measurement capability
20.0- 60.0 mm.± 0.01 %.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-10 by measurement with standard Vernier caliper.

Height of hammer
Parameter / Range / ItemCalibration measurement capability
200.0- 610.0 mm.± 0.25 %

Standard / Technique / Method / EquipmentIn-house method WI 7.2-10 by measurement with standard Vernier caliper.

Horizontal level verification
Parameter / Range / ItemCalibration measurement capability
0.0- 150.0 degree.± 0.2 degree.

Standard / Technique / Method / EquipmentIn-house method WI 7.2-10 by comparison with standard Gauge block.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Oven (Geer Oven)

Temperature Accuracy
Parameter / Range / ItemCalibration measurement capability
100 – <150 °C± 1.50 °C
150 – <200 °C± 1.80 °C
200 – <250 °C± 2.10 °C
250 – <300 °C± 2.50 °C

Standard / Technique / Method / EquipmentIn-house method WI 7.2-09 by direct comparison to standard Thermometer.

Air flow rate
Parameter / Range / ItemCalibration measurement capability
0.3 to 10.0 m/s± 1.20 m/s

Standard / Technique / Method / EquipmentIn-house method WI 7.2-09 by direct comparison to standard Anemometer.

Calibration and measurement capability is expressed as an uncertainty (±) which, for k = 2, provides a level of confidence of approximately 95%.

Ask us for the full accredited scope document.

Request a calibration quote