- ASTM D4169-16
- IEC 61215
- IEC 61646
- IEC 61108
- IEC 62688
- MIL-STD-811D
- SAE J575
- IEC 60068
- ISO 16750
- MIL-STD-810
- IEC 60751
- IEC 60068-2-2
Temperature Chamber
LIB · Temperature & Humidity Chambers
Designed for accelerated reliability testing in R&D and quality inspection and covering a wide range of test volumes and performance demands, the LIB industry temperature chamber precisely simulates extreme thermal environments to identify product risks before market launch. The temperature range covers –20 ℃, –40 ℃, or –70 ℃ up to +150 ℃ , with ±0.5 ℃ temperature fluctuation to ensure stable and repeatable performance. Standard heating and cooling rates reach 3–5 ℃/min , while customized ramp rates are available to meet special test profiles, rapid thermal cycling, or non-standard requirement
Datasheets
- Lib Th Chamber Cataloglib-th-chamber-catalog.pdfDownload PDF
- Lib Industry Temperature Humidity Chamber User Manuallib-industry-temperature-humidity-chamber-user-manual.pdfDownload PDF
- Lib Industry Temperature Humidity Chamber Applicable Standardslib-industry-temperature-humidity-chamber-applicable-standards.pdfDownload PDF
- Lib Industry Temperature Humidity Chamber Maintenance Processing Listlib-industry-temperature-humidity-chamber-maintenance-processing-list.pdfDownload PDF
- User Manual For Temperature Humidity Chamberuser-manual-for-temperature-humidity-chamber.pdfDownload PDF
Designed for accelerated reliability testing in R&D and quality inspection and covering a wide range of test volumes and performance demands, the LIB industry temperature chamber precisely simulates extreme thermal environments to identify product risks before market launch. The temperature range covers –20 ℃, –40 ℃, or –70 ℃ up to +150 ℃ , with ±0.5 ℃ temperature fluctuation to ensure stable and repeatable performance.
Standard heating and cooling rates reach 3–5 ℃/min , while customized ramp rates are available to meet special test profiles, rapid thermal cycling, or non-standard requirements. Multiple configurations—including benchtop, floor-standing, and walk-in designs —support flexible laboratory layouts. Chamber volumes are available from 50 L to 2000 L and larger , accommodating both compact samples and full-scale assemblies.
Available Models
T-100 | T-225 | T-500 | T-800 | T-1000
Compliant Standards
AAMA 501 · ASTM D4169-16 · IEC 61215 · IEC 61646 · IEC 61108 · IEC 62688 · MIL-STD-811D · SAE J575
Temperature Chamber Features and Benefits
1. Wide Temperature Range & Configurable Low-Temperature Options
Capable of operating from –70 °C up to +150 °C or higher , the chamber accommodates extreme cold, high-temperature, and thermal shock pre-tests. Multiple low-temperature settings ( –20 °C, –40 °C, –70 °C ) allow precise matching to test requirements, preventing over-specification and reducing unnecessary procurement costs.
2. Stable Long-Duration Operation
Designed for extended testing, it supports continuous operation for 1000–3000 hours , making it ideal for aging, reliability, and lifespan verification without interruption.
3. Programmable Temperature Ramp & Multi-Stage Profiles
Customizable heating and cooling rates enable different stress levels for each product stage, avoiding over-stressing and unrealistic failures. Multi-stage temperature curves—including gradient ramps, step cycles, and thermal shock simulations—faithfully replicate real-world conditions.
4. Live Testing & Versatile Sample Compatibility
Supports powered (live) testing, allowing products to operate under test conditions for real-time observation of functional stability. Compatible with various sample types, including electronic components, PCBs, complete assemblies, and modules made of metal, plastic, or composite materials.
5. Compliance with International Standards & Certification Support
Meets IEC, ISO, ASTM, MIL-STD, SAE standards, facilitating global product certification such as CE, UL, TÜV, ETL , and ensuring products are ready for market access with recognized testing credentials.
Temperature Chamber Specifications
Configuration of Temperature Chamber
Customization & Expandability
Size & Volume: Tailored to fit specific samples or lab layouts
Temperature Range & Ramp Rate: Adjustable to match precise test profiles
Observation Windows & Feed-Throughs: Optional for real-time monitoring
Special Sample Fixtures: Custom clamps and holders for diverse materials
Software Functions: Programmable multi-stage profiles, automated sequences, and advanced data logging
Worldwide Support & Fast Response
LIB industry provides a 3-year warranty and lifelong technical guidance. Our English-speaking support team responds within 1–3 hours , 24/7 worldwide. Critical spare parts are stocked internationally for delivery in 7–15 days , with clear instructions for safe shipping, installation, and operation.
Get Started Today: Contact us inquiry@libtestchamber.com for a customized solution, fast quotation, and expert guidance for your temperature chamber.
Send Inquiry
LIB Team will send you specs and quote today.
SUBMIT
Key features
• Size & Volume: Tailored to fit specific samples or lab layouts
• Temperature Range & Ramp Rate: Adjustable to match precise test profiles
• Observation Windows & Feed-Throughs: Optional for real-time monitoring
• Special Sample Fixtures: Custom clamps and holders for diverse materials
• Software Functions: Programmable multi-stage profiles, automated sequences, and advanced data logging
Applicable standards (full list as cited by the manufacturer)
ASTM D4169-16, IEC 61215, IEC 61646, IEC 61108, IEC 62688, MIL-STD-811D, SAE J575, IEC 60068, ISO 16750, MIL-STD-810, IEC 60751, IEC 60068-2-2, GB/T 2423.2, ASTM D5423, ISO 16750-4, JESD 22-A103, ISO 9001, ASTM C666, ASTM D714, ISO 9142
Model comparison
| Model | T-100 | T-225 | T-500 | T-1000 |
|---|---|---|---|---|
| Internal Dimension (mm) | 400*500*500 | 500*600*750 | 700*800*900 | 1000*1000*1000 |
| Overall Dimension (mm) | 900*1050*1620 | 1000*1140*1870 | 1200*1340*2020 | 1500*1540*2140 |
| Interior Volume | 100L | 225L | 500L | 1000L |
| Heat load | 1000W | |||
| Temperature Range | A : -20℃ ~ +150 ℃ B : -40℃ ~ +150 ℃ C: -70℃ ~ +150 ℃ | |||
| Temperature Fluctuation | ± 0.5 ℃ | |||
| Temperature Deviation | ± 2.0 ℃ | |||
| Cooling Rate | 1 ℃ / min | |||
| Heating Rate | 3 ℃ / min | |||
| Cooling system | Mechanical compression refrigeration system | |||
| Refrigerating unit | French TECUMSEH compressor | |||
| Heating Element | Nichrome heater | |||
| Controller | Programmable color LCD touch screen controller, Ethernet connection | |||
| Water supply system | Automatic water supply, Water purification system | |||
| Safety Device | Over-temperature protection; Over-current protection; Refrigerant high-pressure protection; Earth leakage protection |
Scroll the table sideways for every column