

- IEC 60068-2-14
- MIL-STD-810G
- IEC 60068-2-2
- ISO 16750-4
- IEC 60068-2-1
- IEC 60068-2-78
- JESD 22-A101
- UL 2580
- SAE J2464
- IEC 60068
- UL 1642
- IEC 61215
Temperature and Humidity Test Chamber
LIB · Temperature & Humidity Chambers
Struggling with unstable 85°C/85%RH tests or long delivery times? LIB industry temperature and humidity test chambers deliver precise control, fast customization, and proven reliability for ESS, aging, and product validation. Temperature humidity climate chambers have 3 low-temperature options : -20 ℃, -40 ℃, -70 ℃ , and the maximum temperature reaches +150 ℃ .Humidity control covers a wide range from 20%RH to 98%RH , ensuring accurate simulation of real-world environmental conditions.
Datasheets
- Lib Industry Temperature Humidity Chamber Applicable Standardslib-industry-temperature-humidity-chamber-applicable-standards.pdfDownload PDF
- Lib Industry Temperature Humidity Chamber Maintenance Processing Listlib-industry-temperature-humidity-chamber-maintenance-processing-list.pdfDownload PDF
- Lib Industry Temperature Humidity Chamber User Manuallib-industry-temperature-humidity-chamber-user-manual.pdfDownload PDF
- Lib Th Chamber Cataloglib-th-chamber-catalog.pdfDownload PDF
- User Manual For Temperature Humidity Chamberuser-manual-for-temperature-humidity-chamber.pdfDownload PDF
Struggling with unstable 85°C/85%RH tests or long delivery times?
LIB industry temperature and humidity test chambers deliver precise control, fast customization, and proven reliability for ESS, aging, and product validation.
Temperature humidity climate chambers have 3 low-temperature options : -20 ℃, -40 ℃, -70 ℃ , and the maximum temperature reaches +150 ℃ .Humidity control covers a wide range from 20%RH to 98%RH , ensuring accurate simulation of real-world environmental conditions.
These chambers are widely applied as thermal humidity chambers for accelerated aging tests, durability evaluation, and environmental stress screening (ESS).
TH Test Chamber Types include:
Benchtop Environmental Chamber TH-50 TH-80
Reach-in Temperature and Humidity Test Chamber
Walk-in Environmental Chamber
Various Models Available | Standard & Customized Chambers Available
Why Leading Laboratories Choose the LIB Temperature & Humidity Chamber
1. Precision Thermal Control
Experience rapid ramp rates and ultra-stable temperatures from -70°C to +150°C . Our high-efficiency heating and cooling systems maintain a fluctuation of ±0.5°C , ensuring your test data is always accurate and compliant.
2. Maintenance-Low Humidity System
Our external isolation evaporation technology prevents water scale buildup and sample contamination. This design ensures stable 10%–98% RH control while significantly extending the lifespan of your sensors and internal components.
3. Versatile System Integration
Maximize your lab's capability with a chamber built for combined testing . Our units easily integrate with vibration, altitude, and ESS systems, allowing you to simulate complex real-world conditions within a single, space-saving footprint.
4. Rapid Customization & Delivery
Don’t settle for "close enough." From custom test ports to reinforced shelving for 100kg+ loads, we provide agile engineering and fast-track delivery for bespoke chambers tailored to your specific testing protocols and lab space.
5. Global On-site Support & 3-Year Warranty
Eliminate downtime with our industry-leading 3-year warranty . We provide expert on-site installation and staff training worldwide, ensuring your equipment operates at peak performance with lifelong technical backup.
Temperature and Humidity Test Chamber Specifications
Highlights of Temperature and Humidity Test Chamber
Typical Tests Performed by Temperature and Humidity Test Chamber
Temperature Cycling
Simulates rapid temperature changes to evaluate product reliability.
Standards: IEC 60068-2-14, MIL-STD-810G
High Temperature Storage
Tests long-term stability under high-temperature conditions.
Standards: IEC 60068-2-2, ISO 16750-4
Low Temperature Testing
Assesses product performance at extreme low temperatures.
Standards: IEC 60068-2-1, MIL-STD-810G
Humidity Aging Test
Evaluates resistance to high humidity and condensation for long-term durability.
Standards: IEC 60068-2-78, JESD22-A101
85°C / 85%RH Reliability Test
Combines high temperature and high humidity to verify product reliability in extreme conditions.
Standards: JEDEC JESD22-A101, IEC 60068-2-78
Download the Full Standards List for Your Temperature Humidity Test Chamber
System Maintenance for Temperature and Humidity Test Chamber Reliable Performance
Heating System : Inspect elements and connections to sustain accurate thermal control and extend service life.
Humidification System : Clean water tanks and filters to guarantee consistent humidity levels and prevent test deviations.
Cooling System : Inspect compressors and refrigerant circuits to ensure stable cooling performance and lower downtime .
Electrical System : Check wiring and control circuits to maintain system safety and fault-free operation .
Other Systems : Inspect moving parts and seals to preserve chamber integrity and operational smoothness .
Download the Complete Maintenance Manual
LIB industry offers 17+ years of experience, 3-year warranty, lifelong support , and global installations. Contact us today for a quote or expert testing solution.
Send Inquiry
LIB Team will send you specs and quote today.
SUBMIT
Key features
• Simulates rapid temperature changes to evaluate product reliability.
• Standards: IEC 60068-2-14, MIL-STD-810G
• Tests long-term stability under high-temperature conditions.
• Standards: IEC 60068-2-2, ISO 16750-4
• Assesses product performance at extreme low temperatures.
• Standards: IEC 60068-2-1, MIL-STD-810G
• Evaluates resistance to high humidity and condensation for long-term durability.
• Standards: IEC 60068-2-78, JESD22-A101
• Combines high temperature and high humidity to verify product reliability in extreme conditions.
• Standards: JEDEC JESD22-A101, IEC 60068-2-78
Applicable standards (full list as cited by the manufacturer)
IEC 60068-2-14, MIL-STD-810G, IEC 60068-2-2, ISO 16750-4, IEC 60068-2-1, IEC 60068-2-78, JESD 22-A101, UL 2580, SAE J2464, IEC 60068, UL 1642, IEC 61215, IEC 62717, ASTM F1980, ISO 22000, ISO 6270, MIL-STD-810, IEC 60068-2-38, MIL-STD-810H, ASTM D2247, ASTM D4169-16, IEC 61646, IEC 61108, IEC 62688, MIL-STD-811D, SAE J575, IEC 60086-4, ISO 16750, MIL-STD-812D, IEC 62804, IEC 62108, UL 1703, JIS C8990
Model comparison
| Model | TH-100 | TH-225 | TH-500 | TH-1000 |
|---|---|---|---|---|
| Internal Dimension (mm) | 400*500*500 | 500*600*750 | 700*800*900 | 1000*1000*1000 |
| Overall Dimension (mm) | 900*1050*1620 | 1000*1140*1870 | 1200*1340*2020 | 1500*1540*2140 |
| Interior Volume | 100L | 225L | 500L | 1000L |
| Heat load | 1000W | |||
| Temperature Range | A : -20℃ ~ +150 ℃ B : -40℃ ~ +150 ℃ C: -70℃ ~ +150 ℃ | |||
| Temperature Fluctuation | ± 0.5 ℃ | |||
| Temperature Deviation | ± 2.0 ℃ | |||
| Humidity Range | 20% ~ 98% RH | |||
| Humidity Deviation | ± 2.5% RH | |||
| Cooling Rate | 1 ℃ / min | |||
| Heating Rate | 3 ℃ / min | |||
| Controller | Programmable color LCD touch screen controller,PC Link, LAN interface for remote control | |||
| Cooling system | Mechanical compression refrigeration system,e nvironmentally friendly refrigerant,compliant with the GWP standards requirements | |||
| Water supply system | Automatic water supply; Water purification system | |||
| Safety device | Humidifier dry-combustion protection; over-temperature protection; over-current protection; Refrigerant high-pressure protection; Water shortage protection, Earth leakage protection; | |||
| Interior Material | SUS304 stainless steel | |||
| Exterior Material | Steel Plate with protective coating |
Scroll the table sideways for every column

